  • 1
  • 2

Brand Name : Kacise

Model Number : KPS210

Place of Origin : China (Mainland)

Certification : certificate of explosion-proof, CE

MOQ : 1pcs

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000 Pieces per Week

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Operating temperature : -30~70℃

Sensor casing (pressure-sensitive diaphragm) : Stainless Steel 17-4PH

Nonlinearity : ±0.5%FS

Electrical connection : Four-core Or Six-core Plug-in

Measuring range : 0~30…160MPa

Power supply : 12~28VDC

Overload : 1.5 Times Full Scale Pressure (maximum 160MPa)

Load resistance : ≤(U-12)/0.02Ω (Second Line)

Contact Now

KPS210 Hammer Union Pressure Sensors

1.Introduction

KPS210 strain gauge high pressure transmitter is a new product that integrates foreign advanced technology and domestic sensor manufacturing technology. It is another crystallization of our company's introduction and digestion of foreign product technology. The sensor adopts imported, high-precision, large resistance strain gauge and domestic unique diaphragm technology. Its measurement range can reach 160Mpa, and it has the characteristics of high response, high precision, strong structure, corrosion resistance, vibration resistance, high performance and high cost performance.

The product is widely used in drilling equipment in the oil industry, especially for high-pressure measurement of imported fracturing vehicles and cementing vehicles. It is the preferred transmitter to replace imported products.

This explosion-proof type meets the requirements of GB3836.1-2010 and GB3836.4-2010 standards, and has obtained the explosion-proof certificate. The explosion-proof mark is Ex ib IIB T6 Gb.

The explosion-proof product is suitable for occasions where explosive gases may appear. The corresponding explosion-proof areas are Zone 1 and Zone 2, and its typical representative gas is propane.

2.Dimension

12-28VDC Power Supply Wing Union Pressure Transducer with Operating Temperature -30-70C

3.Technical Parameters

Measuring range 0~30…160MPa
Overload 1.5 times full scale pressure (maximum 160MPa)
Nonlinearity ±0.5%FS
Zero error ±1%FS
Full range error ±1%FS
Insulation resistance 250M℃@250V DC
Operating temperature -30~70℃
Explosion-proof type -30~60℃
Storage temperature -40~70℃
Power supply 12~28VDC
Output signal 4~20m ADC (Second line)
Load resistance ≤(U-12)/0.02Ω (Second line)
Enclosure protection IP65
Electrical connection Four-core or six-core plug-in
Intrinsic Safety Ex ib IIB T6 Gb
Intrinsic Safety Parameters Ui= 28VDC.Ii=200mA.Pi=1.4W.Ci=0.048μF,Li=0mH
Electronic casing stainless steel 304
Sensor casing (pressure-sensitive diaphragm) stainless steel 17-4PH
Seal nitrile rubber or welding

4. Transport, packaging and storage

4.1 Transport

Check whether the instrument has been damaged during transport. If there is obvious damage, please contact us.

4.2 Packaging and storage

Do not remove the packaging before installation.

4.3 Permissible conditions for storage:

Storage temperature: -40~+70 °C

Storage humidity: 45%~75% relative humidity (no condensation)

5. Installation

The pressure sensitive element used in this product transmits pressure through the pressure-sensitive diaphragm. Any touch will cause damage to the transmitter.

▶ Do not touch the inside of the pressure interface in any way.

5.1 Installation preparation

Check that the appearance of the transmitter is good;

The sealing surface of the pressure interface of the transmitter is clean and undamaged;

Consider the applicability of the measured medium;

The ambient temperature and medium temperature must be within the product technical specifications;

There is enough space for safe electrical installation.

5.2 Transmitter installation and sealing method: Union 2”#1502

12-28VDC Power Supply Wing Union Pressure Transducer with Operating Temperature -30-70C

5.3 Transmitter electrical system

The product matching plug-in is a waterproof plug-in. To ensure the product protection level, be sure to lock the connector during electrical connection.

Power supply: See the product label for details (the power supply must meet the requirements of relevant standards, and the power supply system should be reliable.) The intrinsically safe explosion-proof transmitter is powered by a safety barrier.

Electrical connection requirements: Select a cable with a diameter that matches the plug cable gland, and the cable gland and plug must be intact.

Electrical connection requirements: See the product label for wiring definition

Product pin definition:

A (red): power supply V﹢

B (black): signal output OUT (two-wire system)

C: empty

D: empty

E (yellow): reset + (calibration)

F (white): reset - (calibration)

5.4 Intrinsic safety transmitter for explosive gas environment use precautions

When intrinsically safe explosion-proof transmitters are used in explosive gas environments for electrical connection, they should be combined with safety barriers to form an intrinsically safe explosion-proof system. The safety barrier and power supply are placed in a safe area, and the intrinsically safe transmitter is placed in a dangerous area. Pay attention to safe grounding.

5.5 Intrinsic safety transmitter for explosive gas environment use precautions

When intrinsically safe explosion-proof transmitters are used in explosive gas environments for electrical connection, they should be combined with safety barriers to form an intrinsically safe explosion-proof system. The safety barriers and power supplies should be placed in the safe area, and the intrinsically safe transmitters should be placed in the dangerous area. Pay attention to safe grounding.

The two-wire 4~20mADC output intrinsically safe system is shown as follows:

12-28VDC Power Supply Wing Union Pressure Transducer with Operating Temperature -30-70C

The maximum allowable distributed capacitance Cc=Co-Ci, the maximum allowable distributed inductance Lc=Lo-Li of the system connection cable between the transmitter and the safety barrier.

The maximum allowable distributed capacitance Cc=Co-Ci,

The maximum allowable distributed inductance Lc=Lo-Li.

Co≥Ci+Cc Lo≥Li+Lc

Uo≤Ui Io≤Ii Po≤Pi

The safety barrier can be freely selected by the user, as long as the parameters meet the above requirements and have an explosion-proof certificate. The installation and use of the safety barrier should be carried out according to the safety barrier instruction manual.

6.Support and Services:

Our Precision Pressure Sensor product comes with comprehensive technical support and services to ensure that you have the best experience with our product. Our support services include installation guidance, troubleshooting assistance, and product maintenance advice. Our aim is to ensure that you get the most out of our Precision Pressure Sensor product and achieve your desired outcomes.

12-28VDC Power Supply Wing Union Pressure Transducer with Operating Temperature -30-70C

7.Packing and Shipping:

Product Packaging:

  • 1 Precision Pressure Sensor
  • User Manual
  • Protective foam padding

Shipping:

  • Shipped via standard ground shipping
  • Expected delivery time: 5-7 business days
  • Tracking information will be provided via email

Product Tags:

Wing Union Pressure Transducer

      

12-28VDC Pressure Transducer

      
Quality 12-28VDC Power Supply Wing Union Pressure Transducer with Operating Temperature -30-70C for sale

12-28VDC Power Supply Wing Union Pressure Transducer with Operating Temperature -30-70C Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0