Sign In | Join Free | My chinacsw.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

7 Years

Home > Wire Rope Vibration Isolator >

GXB28-900 test data anti wire rope vibration isolators machine tool equipment

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

GXB28-900 test data anti wire rope vibration isolators machine tool equipment

  • 1
  • 2
  • 3

Brand Name : Kacise

Model Number : GXB28-900

Place of Origin : China

MOQ : 1

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100+

Delivery Time : 5-8 work days

Packaging Details : carton

Length : 370mm

Width : 235mm

High : 216mm

Mounting holes : M12

Resonant frequency : 5-10HZ

Outer mounting hole distance/L1(mm) : 268/266.7

Inner mounting hole distance/L2(mm) : 114/114.3

Maximum vertical deformation (mm) : 125.7

Vertical static load (Kg) : 543

Vertical static stiffness (Kg/mm) : 58.5

Vertical dynamic stiffness (Kg/mm) : 18

45° maximum deformation (mm) : 177

45° static load (Kg) : 325

45°Static Stiffness(Kg/mm) : 32

45° dynamic stiffness (Kg/mm) : 8.9

Maximum deformation of side suspension (mm) : 132

Side hanging static load (Kg) : 111

Side hanging static stiffness (Kg/mm) : 11.2

Side suspension stiffness (Kg/mm) : 8.2

Material : SS304

Weight (kg) : 12.7

Whether to support product customization : Yes

Contact Now

Product Description
Helical Wire Rope Isolators are available in a wide range of sizes to permit attachment to almost any machinery or enclosure regardless of weight
Compact, low profile design and the ability to attenuate heavy shock loads with minimum deflection allows use where space is at a premium
Three-plane, all-axes isolation means that the equipment is free to move in any direction – vertically, horizontally and laterally
Custom winding, loop count and mounting features are available to meet specific requirements
Special cable materials (galvanized steel and other stainless steel alloys), special bar materials (stainless steel, titanium finish platings) and special mounting configurations (inserts, thread types, clearance holes) to name just a few are available

Product Size Chart

Product number High(mm) Width(mm) Product weight(kg) Installation method Hole size(mm) Thread size(mm) Counterbore taper
JGX-286-8-X-16860-A-S 216 ± 6.35 235 12.7

A, B, C, D, E, S

Ø13.5 + 0.13- 0.38 M12X1.75 90°


Press Fit Test Data Sheet

Curve number Product number Static load(N) Maximum deformation (mm) Vibration stiffness Kv kN/m Impact stiffness Ks kN/m
1 JGX-286-8-X-16860-A-S 5430 125.7 585 180


45° Inclined Press Fitting Load Test Data Sheet

Curve number Product number Static load(N) Maximum deformation (mm) Vibration stiffness Kv kN/m Impact stiffness Ks kN/m
1 JGX-286-8-X-16860-A-S 3250 177.8 327 89


Shear Rolling Load Test Data Sheet

Curve number Product number Static load(N) Maximum deformation (mm) Vibration stiffness Kv kN/m Impact stiffness Ks kN/m
1 JGX-286-8-X-16860-A-S 1110 132.1 112 112


GXB28-900 test data anti wire rope vibration isolators machine tool equipment
Wire rope vibration isolators have the following advantages:

  • Rugged, metal construction
  • Low frequency, highly damped vibration isolation
  • Excellent shock attenuation
  • Wide temperature range, -200°F to +650°F
  • Fail-safe construction
  • Maintenance-free

Product structure diagram
GXB28-900 test data anti wire rope vibration isolators machine tool equipment
Guide for installation of wire rope isolator
1. Before installation, please carefully check whether the mounting hole matches the mounting hole of the vibration isolator, such as whether the thread is the same, etc.
2, the installation hole is clean, there is no burr, rust, damage and other defects.
3. Since the vibration isolator is an elastic component, it needs a little movable space when working. Before installation, please carefully check whether there is any equipment affecting installation in the installation part and whether the movable space of the vibration isolator is enough. Please check whether the vibration isolator is in good condition and has no defects before installation.
4. Prepare a suitable screwdriver and crowbar.
5, first install the isolator to heavy equipment or fixed equipment, installation screws do not need to tighten, so that the isolator can be slightly active.
6. Install the connecting device on the other side of the vibration isolator. If the mounting hole is slightly misaligned, you can move the vibration isolator or use a crowbar to align the mounting hole of the vibration isolator with the mounting hole of the equipment, and then screw the fixing screw.
7. After fixing the device position, tighten all the fixing screws.
Application

  • Airborne avionics and equipment
  • Shipboard/Marine equipment and electronics
  • Mobile equipment and electronics
  • Computer equipment and disc drives
  • Blowers and Fans
  • Motors and Pumps
  • Medical Equipment
  • Motor Generators and Compressors
  • HVAC Equipment

GXB28-900 test data anti wire rope vibration isolators machine tool equipment


Quality GXB28-900 test data anti wire rope vibration isolators machine tool equipment for sale

GXB28-900 test data anti wire rope vibration isolators machine tool equipment Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0